These diagrams were copied from the ImageFX Manual from Nova Design. Nova Design includes this disclaimer:
Nova Design Inc, provides this information as a service to the user community. Nova Design assumes no responsibility for damage to equipment resulting from incorrect use of this information.
GVP-Specified Cable Connections:
DB24 Male | Centronics 36 Male | Pin | Signal | Pin | Signal | 2 | D0 | 2 | D0 | 3 | D1 | 3 | D1 | 4 | D2 | 4 | D2 | 5 | D3 | 5 | D3 | 6 | D4 | 6 | D4 | 7 | D5 | 5 | D5 | 8 | D6 | 8 | D6 | 9 | D7 | 9 | D7 | 10 | ACK* | 10 | ACKNLG* | 11 | BUSY | 11 | BUSY | 12 | POUT | 36 | DIR | 13 | SEL | 1 | STROBE* | 16 | Reset* | 31 | INIT* | 22 | GND | 30 | GND | 25 | GND | 33 | GND | ASDG Specified Cable Connections:
---|
DB24 Male | Centronics 36 Male | Pin | Signal | Pin | Signal | 1 | STROBE* | NC | NC | 2 | D0 | 5 | D3 | 3 | D1 | 8 | D6 | 4 | D2 | 7 | D5 | 5 | D3 | 4 | D2 | 6 | D4 | 2 | D0 | 7 | D5 | 9 | D7 | 8 | D6 | 3 | D1 | 9 | D7 | 6 | D4 | 10 | ACK* | 10 | ACKNLG* | 11 | BUSY | 11 | BUSY | 12 | POUT | 1 | STROBE* | 13 | SEL | 36 | DIR | 14 | +5V | 14 | NC | 15 | NC | 32 | NC | 16 | Reset* | 31 | INIT* | 17 | GND | NC | NC |
---|